servicel@daelim-electric.com
+86-13121593340

WHAT ARE THE STANDARD ACCESSORIES FOR PAD MOUNTED TRANSFORMER

accessories of pad mounted transformer (1)

Thanks to our years of experience and our professional team, Daelim can support customized transformers according to our clients requirement. Daelim cares about the quality and the details of our transformers offering the best solution to our customers all over the world. In this article we will introduce Daelim Pad mounted transformer and its accessories.

Each client requires different characteristics for the transformers they are asking for, and also different accessories. In this article we will see the different pad mounted transformer accessories and how the price can vary according to customers requirements.
 
If you want to learn more about the parts and components of Pad mounted transformer, check out this article. 

Pad-mounted Transformer

We can provide you single phase and three phase pad mounted transformer

Dry-type Transformer

Type:Cast resin; Rated Capacity: Up to 25MVA; Rated Voltage: Up to 36KV;

Pole Transformer

TypeCSP type Frequency: 50/60Hz; Rated Power: 5~167kva

Oil immersed transformer

Frequency: 50/60Hz Rated voltage:10kv, 20kv,30kv Rated Power: 400~2500kva

Table of Content

FUSES OF PAD MOUNTED TRANSFORMER

accessories of pad mounted transformer (2)

Pad mounted transformers are equipped with a two fuse system, one is bayonet fuse (RTE) and the other one is current limiting fuse (CLF).
 
Bayonet fuses are used to protect distribution equipment from damaging currents and to protect distribution systems from failed equipment.
 
Bayonet fuses are ideal for use in a two – fuse protection scheme with a current – limiting backup fuse.
 
For dual – voltage transformers, the current limiting backup fuse shall have a fuse voltage rating suitable for the higher voltage and a current rating adequate for the lower voltage. Expulsion fuses for both voltages and corresponding currents shall be provided, and the fuse for the higher voltage shall be installed, unless the customer need different requirement.
 
Pad mounted transformer are equipped with 3 Bayonet fuses and 3 fuses, with the function of protecting the transformer, as we mentioned before. 

HIGH VOLTAGE BUSHING OF PAD MOUNTED TRANSFORMER

High voltage bushings are important equipment in the power distribution

accessories of pad mounted transformer (3)

For Pad mounted transformers we have different configurations, Loop Feed Pad mounted transformer and Radial Feed Pad mounted transformer. These two different types of configuration, also require different quantity of accessories. In the case of Loop Feed, the transformer is equipped with 6 HV bushings and Radial Feed is equipped with 3 HV bushings.
 
High Voltage bushings have the function of current carrying and insulation when the high voltage line passes through the wall and equipment core, and the connection between equipment or the grounding equipment.

LOW VOLTAGE BUSHING OF PAD MOUNTED TRANSFORMER

Low voltage terminals shall be the spade type and shall have a thickness that will provide adequate ampacity.

Low voltage terminals should be clamped polymer and porcelain with 4-12 Hole spades.

Read my article on Know More About Tips of single phase transformer

CORE AND COIL OF PAD MOUNTED TRANSFORMER

The coil of Daelim Pad mounted transformer is manufactured with high quality cutting machine, ensuring high quality and perfection in the details. The most common is three – legged mitered core construction, ensuring the best performance. Five – legged cores designs are used in different types of transformers, with a special design (wye-wye connection).

At the same time, the coil is designed to minimize the axial stress of short circuit, providing high quality windings. Cores are manufactured with precision cut, grain oriended, and silicon steel, and designed to optimize core loss efficiency.
 
Daelim Pad mounted transformers feature a rectangular coil configuration with wire wound, high voltage primaries and sheet wound secondaries.
 
The assemblies of the core and the coil are braced with heavy steel ends to prevent the rectangular coil from distorting under short circuit conditions, and exceed ANSI and IEEE requirements for short circuit performance.

Try for free information about the VENEZUELA CUSTOMERS

TANK OF PAD MOUNTED TRANSFORMER

The tank of Daelim Pad mounted transformer are designed for high strength and easy of handle, installation and maintenance. They are sealed to protect the insulating fluid and other internal components.
 
The transformer base shall be arranged so that the tank bottom does not touch the pad.
 
In terms of the process of tank production, Daelim pay attention of the precision cuts, oiled steel, pickling, etc. All the materials that Daelim use for the process of production of Pad mounted transformer tank, are high quality and resistant to corrosion. In this way we extend the life of the tank and the transformer as well.  
 
Like the core and coil assemblies, the tank also follow the requirements of the IEEE standards.
 
The color used for the tank is Munsell Green, with the markings in white. These markings are transformer capacity (kVA), primary and secondary voltageg, serial number, and should be painted in white outside, located in the high voltage door.

Keep on reading VIETNAM CUSTOMERS

OIL LEVEL INDICATOR, PRESSURE RELIEF VALVE, PRESSURE VACUUM GAUGE, THERMOMETER FOR PAD MOUNTED TRANSFORMER

accessories of pad mounted transformer (4)

OIL LEVEL INDICATOR

The Oil level indicator of Pad mounted transformer is response of the need of maintenance professionals to gauge the oil level inside the tank. 

PRESSURE RELIEF VALVE

Pressure relief valve are specially designed for safety and protection.

The application of the pressure relief valve is to limit a sudden rise in oil pressure, inside a free – breathing oil cooled transformer tank.

PRESSURE VACUUM GAUGE

The pressure vacuum gauge indicated wether the gas space in the tank is under positive or negative pressure. This pressure depends on the transformer temperature. The pressure will be negative when the transformer is de – energized or operating under light load in low ambients.

THERMOMETER

The main function of the thermometer in pad mounted transformer is measure the oil temperature. Daelim Pad mounted transformer thermometer provide the temperature of the oil accurately, thus helping to have a better function of the transformer.
 
The thermometer helps us to check the working status of pad mounted transformer and make sure that works in the correct way.
 
The temperature rise of the insulating oil shall not exceed 65 degrees when measured near top oil level.

Learn more about 3 Phase Transformer Power Transformer Manufacturer Daelim

NAMEPLATE OF PAD MOUNTED TRANSFORMER

accessories of pad mounted transformer (5)

All pad mounted transformers should be equipped with a combined name plate and connection diagram. The nameplate shall contain the following information:
 
– Pad mounted cooling type

– number of phases

– rating in kilovolt amperes

– Identification number

– Impedance

– Oil volume in litres

– BIL (Basic Impulse level)

– total mass (including the liquid)

– rated high and low voltage

– Bayonet fuse and CLF fuse identification

– Tap voltage

– Diagram of connection and vector diagram

– Date of manufacture

– name of manufacture

– Energy efficiency

– Approval steps

TAP CHANGER OF PAD MOUNTED TRANSFORMER

accessories of pad mounted transformer (6)

Tap changer of pad mounted transformer function is increase or decrease the output secondary voltage by changing the turn ratio of primary or secondary winding. This is installed in high voltage side.
 
Off – circuit tap changer and dual voltage selector switches, when specified, shall be externally operable lever – handle types, made of corrosion – resistant material. The means for operating the pad mounted transformer tap changer shall be installed in the cable entrance compartment. The highest voltage tap shall be tap position 1.

You may interested in 15kva transformer Tips

COOLING METHOD OF PAD MOUNTED TRANSFORMER

Daelim Pad mounted transformer normally use mineral oil or commonly known as transformer oil for their cooling method. Also are available with electrical grade mineral insulating oil or FR3 fluid. The applied liquids are to improve the efficiency, to low the risk of accidents, and the most important, to collaborate with the environment.

FR3 oil ensure safety and environmental benefits of the transformer and at the same time, improve also the life of the pad mounted transformer in this case.

Depends on the oil used for the transformer, also the price will be different. In the case the FR3 vegetable oil, the price will be also higher than mineral oil.

Know more about 25 kv oil immersed transformer  DAELIM

LOAD BREAK SWITCH OF PAD MOUNTED TRANSFORMER

Load break switch of pad mounted transformer are designed to switch the power on – off, or change the position when the transformer is energized (has a load on it) and the switch will break it. In resume, is primarily utilized to open an electrical circuit by isolating the source from the customer. This can be manual or motorized. Load break switch ensure on load markings, safety disconnections and breaking.
  
In addition to three-phase pad mounted transformer, Daelim also has single-phase pad mounted transformer.

Try for free Where is a 33 kv Distribution Transformer Used for?

Download Resource

About Daelim

Recent Posts

About Bin Dong

Hello, I am Bin, General manager of Daelim which is a leading transformer manufacturer. If you have problems when you are looking for the equipment, what you need to do is tell us.